thermal fuse
Listing ID#10051982
ModelHX
CategoryElectrical Contacts and Contact Materials

thermal fuse

Specifications

Origin
guangdong
Price Term
FOB
Request Quote
Quick answer

thermal fuse is a Electrical Contacts and Contact Materials product. Key specs — Origin: guangdong; Price Term: FOB.

Product Description

Product description
TH-AID universal and enhanced serial thermal protectors are widely used in industry, electrical household appliance and electric equipment to avoid abnormal operation caused by overcurrent and overtemperature. The products provide effective, reliable and safe protection. The enhanced casing is suitable for internal installation of plastic hermetic motor, which can bear the plastic molding pressure at 3.5Mpa. The performance of the products satisfies the standards including IEC34-11, GB13232, GB/T13002, etc.


Structure and protection principle
TH-AID type thermo protector is composed of the parts of thermal conductive casing, bimetallic parts welded with silver alloy contact point, conductive bracket, insulation fixation stand, fixed contact strip and heat resistance cable. When current passes through the bimetallic parts with resistance and in case of abnormal operation, along with the increase of current or the environment temperature rises to the set value, the bimetallic parts perform quick action, opens the contact point, and disconnects the circuit. When the device is cooled to the temperature for safe operation, the contact point will automatically closes and recover normal operation.


Structure figure


nbsp;

 

Note
1.Because the casing is made of conductive metal, thermal conductive and heat resistance insulation sleeves are required for use.
2.Refer to A-C graph for selecting protection temperature.


Rated action temperature table


Type

Open Temperature Range

Type

Open Temperature Range

50℃

50±5.0℃

100℃

100±5.0℃

55℃

55±5.0℃

105℃

105±5.0℃

60℃

60±5.0℃

110℃

110±5.0℃

65℃

65±5.0℃

115℃

115±5.0℃

70℃

70±5.0℃

120℃

120±5.0℃

75℃

75±5.0℃

125℃

125±5.0℃

80℃

80±5.0℃

130℃

130±5.0℃

85℃

85±5.0℃

135℃

135±5.0℃

90℃

90±5.0℃

140℃

140±5.0℃

95℃

95±5.0℃

145℃

145±5.0℃

 

 

150℃

150±5.0℃

Note: The recovery temperature is 2/3 of the standard action temperature with the tolerance of ±15℃ or specified by customer

 


Contact point maximum capacity
TH serial protectors can perform 5000 times of connection and disconnection protection under the following conditions.


Voltage

24V-DC

125V-AC

250V-AC

Current

12A

12A

8A

Installation and overall dimensions


nbsp;

Cable
The cables are AWG20#, 22# silicone cable and electronic irradiated cable. Customized service is available.
A-C graph
Critical current & ambient temperature graph (It is to consider current effect while selecting the protection temperature)


nbsp;

Passed certifications


nbsp;

Related Products