Smart Energy Meter for Digital Substation
Specifications
- Origin
- Yantai City,Shandong Province,China
Smart Energy Meter for Digital Substation is a Electricity Generation product. Key specs — Origin: Yantai City,Shandong Province,China.
Product Description
Accuracy Class 0.2S and Class 0.5S IEC62053-22(Class 0.2Sand 0.5S)IEC62053-23(Class 2) IEC61850 9-1,IEC61850 9-2 Compliance with DLMS/COSEMMeasurement Mode: Single Phase (3 Circuits) 3 Phase 3 Wire 3 Phase 4 Wire Compatibility for switch and non-switch modes Measured Energy Values 3 Elements, 4 Quadrants Import/Export KWh, Kvarh and KVah Per quadrant Wh, varh and Vah Absolute Wh, varh and VAh Phase A, B, C & Total Other Measured and Displayed Values W, var, KVA True RMS Voltage(3 Phase) True RMS Current(3 Phase) Power Factor Frequency Phase Angles Voltage&Power Supply Nominal Voltage: 57.7-240 L-N Operating Limit: 46-290 L-N Frequency Range:45Hz-65Hz(National Deviation Involved) Option for Auxiliary Supply&UPSCurrent CT Range: 0.3/1.2A,1/4A,1.5/6A,5/20A CT Meter: 20 times Imax for 0.5 seconds WC Range: 5/100A,10/100A,15/60A,20/100A,30/120A(Class 1) WC Limit: 30 times Imax for 0.5 cycles Burden:less than 0.5VA/phase Load Survey/Load Profile Up to 2 Megabytes of Non-Volatile Memory Over 600 Days Storage(8 Channels, 15-Minute Intervals) Intervals Programmable from 1 to 60 Minutes Energy, Instantaneous Readings as Channel Sources Ability to Store Average/Maximun/Minimum Values for Interval Duration for Individual Channels Time of Use 4 Rates Plus Unified Rate Daily, Weekly, Monthly, Yearly&Special Up to 200 Programmable Special Days Up to 61 Previous Periods plus Period Totals Block or Rolling Maximum Demand Energy, Pulsing Inputs Time of Maximum Demand Power Quality Indication Total Harmonic Distortion(THD) Sequence Components Waveform Download Environmental Operating Range: -10℃~+55℃ Limit Range: -10℃~+65℃ Relative Humidity: Up to 95% non-condensing for 30 days Time Clock&Calendar Accuracy (internal) within 15 Seconds per Month at 23℃ Backup Time of 10 Years without Power(Lithium Battery) Internal Crystal TimingLCD Display Graphical interfaces 6 integral with 2 decimal or 5 with 3(programmable) Programmable units, multipliers and leading zeros Up to 119 user definable screen displays Displays any available meter parameter Security Multi-level Security(Username&Password including Encrypted Log-in) Up to 3 Independent Security Levels Up to 3 Individual Users Tamper Detection& Alarms Provision for Sealing with Lead Seals Bypassing&Reverse Current Advanced Tamper Detection and Logging Pre-programmed Alarms for Meter Self-check Alarms Trigger LEDs, Relay Outputs or Communication Events Alarms are Stored in Event Logs Communications RS485 Port(MODBUS, IEC62056-21 (IEC1107),DLMS/COSEM compliant, or other provided protocols) IR Port RJ45(10M/100M) Optical interface-SC(optical wavelength 1300nm,100M), IEEE802.3u 100Base-FX compliant UDP/IP GPRS/PPP Capable Physical Dimensions Standard Version:282mm(L) × 166mm(W) × 85mm(D) Weight:Approximately 1Kg Software Wisdom Software Available for Meter Programming&Reading(Windows 7/Vista/XP/2000)