Shear beam load cell is a Sensors product. Key specs — Brand: SILVANUS; Origin: China (Mainland).
Product Description
Type | XBB | ||
Accuracy class Maximal numbers of load cell verif.intervals(nLc) | D1 1000 | C3 3000 | |
Max. capacity(Emax) | t | 0.1,0.30.5,2,2.5,3,5,7.5,10 | 0.1,0.30.5,2,2.5,3,5,7.5,10 |
Minimun load cell verification interval (vmin) | Cn | 0.0360 | 0.0100 |
Sensitivity(Cn) | mV/V | 2 | |
Tolerance of sensitivity | % | ?+1;-0.1 | ?±0.05 |
Temperature effect on sensitivity (TKc) | % of Cn/10K | ?±0.0500 | ?±0.0100 |
Temperature effect on zero balance (TKo) | % of Cn/10K | ?±0.0500 | ?±0.0125 |
Non-linearity (dlin) | % | ?±0.0500 | ?±0.0170 |
Hysteresis error (dhy) | % | ?±0.0500 | ?±0.0170 |
Creep (dDR) in 30min | % | ?±0.0500 | ?±0.0170 |
Input resistance (RLC) (black-blue) | Ω | >350 | |
Output resistance (R0) (red-white) | Ω | 350±2 | 350±1.5 |
Reference excitation voltage (Uref) | V | 5 | |
Nominal range of excitation voltage (Bu) | V | 5…15 | |
Insulation resistance (Ris) | GΩ | ?5 | |
Nominal temperature range (BT) | ? | -10?+40 | |
Servicetemperature range (Btu) | ? | -15?+85 | |
Storage temperature range (Btl) | ? | -15?+85 | |
Safe load limit (EL) | % of Cn | 150 | |
Breaking load (Ed) | % of Cn | 300 | |
Protection class
| |||