PROFIBUS DP Redundant Link Module
Listing ID#75708
ModelCi-pp21
CategoryTelecommunications

PROFIBUS DP Redundant Link Module

Specifications

Brand
Comark
Origin
China
Certifications
CE, FCC, RoHS
MOQ
1 pair
Packaging
Standard Carton
Price Term
EX-Work
Payment Term
T/T/Western Union/MoneyGram
Supply Ability
1,000 pcs per week
Delivery Time
4 to 5 days
Loading Ports
Shenzhen
Guarantee
1 year warranty
Request Quote
Quick answer

PROFIBUS DP Redundant Link Module is a Telecommunications product. Key specs — Brand: Comark; Origin: China; Certifications: CE, FCC, RoHS; MOQ: 1 pair.

Product Description

Profibus dp fieldbus fiber optic repeater achieve the long distance transmission by fiber optic of Siemens dp fieldbus, can be a substitute for the Siemens imported models: OLM G11/12/22 fiber optic link module. Profibus dp fieldbus fiber optic repeater successfully used for Thermal Power Plant Assist Network Control, Coal Dressing Auto-Control, Mine Belt Conveyor, Wind Power Converter, Variable Frequency Drive, mine hoisting, AC and DC Speed Control, Hydropower Station, Metallurgy EIC Control, Waster Water Treatment, Blast Furnace Control, Coke Oven Automation, Automatic Line, Sinter Plant and other projects. Profibus dp redundant link repeater is upgraded on the original model Ci-pf110/120, there are 2 groups of profibus dp interface, which can simultaneously transmit 2 channels of profibus dp fieldbus signal on the upgraded equipment, and the 2 groups of fiber ports can make up fiber-optic ring network, the system will rebuild the network link within 10ms when the link failures somewhere, to guarantee the system communicate normally, achieve the function of self-healing protection of signal transmission, the system will automatically recover after the network failure recovery.

profibus dp fieldbus fiber optic repeater achieve the function of the transformation between electrical signal and fiber optic signal of profibus do fieldbus. Equipment featured: adopting the mode of directly forwarding, no frame loss, higher reliability and real-time; low time-delay supply the guarantee of real-time; dual power supply circuit built-in the machine can achieve the true dual power redundant backup; which adopts the high-quality power module to supply 1000V voltage isolation; solid and beautiful DIN rail design with aluminum alloy and wave pattern casing; adopting the parts with famous brand and industrial grade, to make products with industrial grade.

#12304;Specifications&#12305

Electrical Interface

#61656; 9-pin Sub_D, socket connector, definition of pins conform to Profibus DP protocol standard.

#61656; Support Profibus DP Standard.

#61656; Communication Rates: 9.6kBit/s、19.2 kBit/s、45.45kBit/s、93.75k kBit/s、187.5kBit/s、500kBit/s、1.5MBit/s、3MBit/s、6MBit/s and 12MBit/s.

#61656; Have the protection function of 4000V anti-lightning,1.5A over-current and 600W surge-proof

#61656; Terminal Resistance: the equipment without terminal resistance, please use the external one when necessary.

Power and Protection #61656; Power: dual power redundancy input, DC(12-36)V, typical DC24V, power consumption less than 4W, has DC1500V voltage isolation and reverse protection, industrial terminal interface.

#61656; Relay alarm output: optical fiber link failure and power error alarm output, maximum capacity of contacts: DC48V/1A, industrial terminal interface.

Mechanical Properties #61656; Dimensions: 132mm×105mm×52mm

#61656; Casing: IP30 protection grade, wave pattern aluminum enhanced casing.

#61656; Installation: 35mmDIN rail installation.

#61656; Net weight: 800g

Environmental #61656; Operating Temperature: -10-70℃ (-40~+85℃ optional)

#61656; Ambient Relative Humidity: ≤90% (non-condensing)

#61656; Storage Temperature: ﹣40~80&#8451

Test Certificate

CE certificate #61656; EN55022:2010(RE) Band Width:120KHz Frequency Range:30MHz to 1000MHz

#61656; IEC61000-4-2:2001(ESD) Air discharge voltage: ±8KV contact discharge voltage: ±4KV

Criterion:B Level 2

#61656; IEC61000-4-3:2006(RS) 3V/m(80-1000MHz)Criterion:A Level 2

RoHS certificate #61656; Test Standards:EN1122:2001 EPA3050B,EPA3052 EPA3540C,EPA3060A

#61656; Testing item:Pb Cd Hg Cr6+ PBBs

#61656; Test Results: N.D.

#12304;Order information&#12305

P/N Series Description Unite

Ci-pp21 1+2 electric Profibus DP standard, 1 port M (DP3), 2 pcs of redundant bus port A (DP1) and port B (DP2). DIP set rate or rate adaptive. pcs

Fiber multiplexer, Fiber networks, Fiber media converters,Fiber Repeater Module, Fiber Optic Communication Modules,Fiber Optic Communication, Fiber Optic transceiver, Fiber optic interface for ring structures, Fieldbus network repeater, Fieldbus transceiver,Optical multiplexer, Optical Fiber Modem/Redundant/Self-Healing, Optical Communication Modules, Optic fiber devices,Multidrop Fiber Optic, Multidrop Fiber Optic Connectivity for Modbus,Configure new network with line or redundant ring structure, Interface protocol converters, Network communication, Protocol converter, 2 Channel Fiber Optic modules for bus star and hub topologies.

Profibus Siemens: OLM G11, Fiber to Profibus, OLM, Optical link module

OLM G11, 6GK1502-2CBXX, 6GK1503-2CBXX

OLM G11-1300, 6GK1502-2CCXX, 6GK1503-2CCXX

OLM G12, 6GK1502-3CBXX, 6GK1503-3CBXX

OLM G12-1300, 6GK1502-3CCXX, 6GK1503-3CCXX

DP HUB: 6ES7972-0AA01-0xA0

Hirschmann: Hirschmann serial, Hirschmann Industrial Networking Products

OZD Profi 12M G11

OZD Profi 12M G11-1300

OZD Profi 12M G12

OZD Profi 12M G12-1300

Phoenix

PSI-mos- profibus/fo 850 E (mm one optic port)

PSI-mos- profibus/fo 1300 E (sm one optic port)

PSI-mos-profibus/fo 850 T (mm dual optic port)

PSI-mos- profibus/fo 1300 T (sm dual optic port)

Related Products