Product Description

Hopper Weighing Controller BST106-B21 is mainly used for weighing systems of hopper scale, platform scale and so on. It adopts ∑-â–³ A/D conversion technology. Max. 8 loadcells are connectable. The functions of zero auto-tracking, key-locking & auto-locking, full digital setting & calibration, Net/Gross weight limit alarm, weight set-point alarm and so on are available.

Technical Specifications:     Power Supply                              Operating Voltage 1:AC220V,-15% to +10%.                   Operating Voltage 2:AC85 to 264V.                     Operating Frequency:50Hz,±2%.                       MAX.Power:20W.    Disply     6-bit red LED digital display and 1 red LED bar display.    Keypad     6 keys forMenu&Shortcut operation with key tone.                Key-Locking and Auto-locking.                   Load cell Signal Input Interface(SENSOR/LOADCELL)              Excitation Voltage Output:DC10V.                   1 Weight Input Signal: 0~30mV or 0/4~20mA.     Wiring Modes: 6-wire, 4-wire and 2-wire.     Max.

Connection Number: 8 Loadcells (350Ω, 0.5~3.0mV/V).    A/D Converter     24-bit ∑-â–³ADC.     Sampling Frequency: Max.

100Hz.    Analog Signal Output Interface(AO)     1 Analog Output Signal: 4~20mA.     Accuracy: ±0.1%FS.    Definable: Net/Gross Weight Signal Output.    Relay Switch Signal Output Interface (DO)     4 Normally Open Relays or Transistor Switch Outputs.     Capacity of Relay Switch: AC250V/DC24V, 1A.     Capacity of Transistor Switch: DC24V, 500mA.     Definable: Net/Gross Weight Uppermost/Upper/Lower/Lowest Limit, Overload Alarm, Calibrating/Weighing State, DI1/DI2/DI3 Signal Output, Serial Port Set, NET(GROSS) ≥ Setpoint, SetpointA ≤ NET(GROSS) < SetpointB, etc.    Switch Signal Input Interface (DI)     3 DI Switch Inputs.     Definable: Zero Calibration, Zero Operation, Tare Operation, Net/Gross Weight Display Operation.    Digital Communication Interface (COM)     COM1: RS232/RS485.     COM2 Optional: RS485, Profibus-DP, Ethernet, CANBUS, Wireless Module (only for BST106-B21), etc.     Connectable: IPC/ PLC, Remote Display, Remote Operating Terminal, Serial Printer, Wireless Module, etc.     Power Supply Output: DC5V, 100mA.