Interpakt
Interpakt is a Trading Company. Main products and services: Geophysical(load-carrying, self bearing) armoured cable.
Company Profile
Our firm represents the manufacturer geophysical load-carrying armored cable in ukraine.
We offer this production -geophysical(load-carrying, self bearing) armoured cable.
It is a lot of years the geophysical cable made at us the fishery companies use.
So, company 'antarctica', from illichivsk fishery port, is one of our steady customers
Of this cable. More than 12 years we deliver our production and we have no any complaint to its quality.
We can make and supply geophysical cables the following types:
- gost kg 1-55-90(standard tehnology europe - asia geophisical association 10-01)
- gost kg 1-30-90(standard tehnology europe - asia geophisical association 10-01)
Cables all types can be maintained in aggressive environments. Below
Fundamental technical characteristics of geophysical cable gost kg 1-30-90(st eaga 10-01)
- outer diameter - 6,5 mm(0,26 in)
- building lenght - 1000-5000 m(3281-16400 ft)
- limit of breaking strength - 30 kn(3059 kg or 6744 lb)
- conductor represents a strand, which
Consists of seven non-insulated copper
Wires, and each of this copper wires has
A diameter in cross-section - 0,37mm(0.02 in)
- piece of condactors - one
- cross-section area of a strand - 0,75 sq. Mm(0.0012 sq. In)
- cable has two layers of an armor,
And each of them consists of Galvanized high-tensile steel-wires:
A) outer armor(rhl) - 13(±1) piece;
B) inner armor(lhl) - 12(±1) piece.
- insulation of a conductor is made of
A polymeric material of the low pressure,
Keeping working-capacity at an
Environment temperature a maximum: - +90°c(194,0°f)
- electric resistance to direct current
A strand of a cable length of 1000 m(3281 ft) - 15-25 ohm
- nominal test voltage, during 5 minutes under
Condition of a environment temperature to
+90°c(194,0°f) - 2000 ~v,50 herz
Fundamental technical characteristics of geophysical cable gost kg 1-55-90(st eaga 10-01)
- outer diameter - 9,4 mm(0,37 in)
- building lenght - 1000-5000 m(3281-16400 ft)
- limit of breaking strength - 55 kn(5608 kg or 12360 lb)
- conductor represents a strand, which
Consists of seven non-insulated copper
Wires, and each of this copper wires has
A diameter in cross-section - 0,37mm(0.02 in)
- piece of condactors - one
- cross-section area of a strand - 0,75 sq. Mm(0.0012 sq. In)
- cable has two layers of an armor,
And each of them consists of Galvanized high-tensile steel-wires:
A) outer armor(rhl) - 17(±1) piece;
B) inner armor(lhl) - 14(±1) piece.
- insulation of a conductor is made of
A polymeric material of the low pressure,
Keeping working-capacity at an
Environment temperature a maximum: - +90°c(194,0°f)
- electric resistance to direct current
A strand of a cable length of 1000 m(3281 ft) - 15-25 ohm
- nominal test voltage, during 5 minutes under
Condition of a environment temperature to
+90°c(194,0°f)